Skip to content
DSC05582-Enhanced-NR
G48 Precast Gels for polyacrylamide gel electrophoresis (PAGE) enable the analysis of 48 samples in approximately the same time as traditional gels. 
G48 product image close
G48 Precast Gels for polyacrylamide gel electrophoresis (PAGE) enable the analysis of 48 samples in approximately the same time as traditional gels.
G48 in use product image close
Easily loadable by pipette - no gel loading tips necessary!
Easily loadable by pipette
Easily loadable by pipette - no gel loading tips necessary!
12-channel and 8-channel pipettes.
G48 Precast Gels are loadable by 12-channel and 8-channel pipettes.
acryl
G48 Precast Gel 6% Acrylamide: Molecular weight separation
G48 10% ladder 25.01.27_06.00.57_PUB_416 2
Result from a G48 Precast Gel (10%) loaded with molecular weight ladder in alternating wells.
g-ladder-xl-2
Result from a G48 Precast Gel (10%) loaded with recombinant alpha-tubulin protein in all wells.

G48 Precast Gel

48-Well Precast Gel for High-Throughput Western Blotting

$35.00

DSC05582-Enhanced-NR
G48 Precast Gels for polyacrylamide gel electrophoresis (PAGE) enable the analysis of 48 samples in approximately the same time as traditional gels. 
G48 product image close
G48 Precast Gels for polyacrylamide gel electrophoresis (PAGE) enable the analysis of 48 samples in approximately the same time as traditional gels.
G48 in use product image close
Easily loadable by pipette - no gel loading tips necessary!
Easily loadable by pipette
Easily loadable by pipette - no gel loading tips necessary!
12-channel and 8-channel pipettes.
G48 Precast Gels are loadable by 12-channel and 8-channel pipettes.
acryl
G48 Precast Gel 6% Acrylamide: Molecular weight separation
G48 10% ladder 25.01.27_06.00.57_PUB_416 2
Result from a G48 Precast Gel (10%) loaded with molecular weight ladder in alternating wells.
g-ladder-xl-2
Result from a G48 Precast Gel (10%) loaded with recombinant alpha-tubulin protein in all wells.
DSC05582-Enhanced-NR
G48 Precast Gels for polyacrylamide gel electrophoresis (PAGE) enable the analysis of 48 samples in approximately the same time as traditional gels. 
G48 product image close
G48 Precast Gels for polyacrylamide gel electrophoresis (PAGE) enable the analysis of 48 samples in approximately the same time as traditional gels.
G48 in use product image close
Easily loadable by pipette - no gel loading tips necessary!
Easily loadable by pipette
Easily loadable by pipette - no gel loading tips necessary!
12-channel and 8-channel pipettes.
G48 Precast Gels are loadable by 12-channel and 8-channel pipettes.
acryl
G48 Precast Gel 6% Acrylamide: Molecular weight separation
G48 10% ladder 25.01.27_06.00.57_PUB_416 2
Result from a G48 Precast Gel (10%) loaded with molecular weight ladder in alternating wells.
g-ladder-xl-2
Result from a G48 Precast Gel (10%) loaded with recombinant alpha-tubulin protein in all wells.

Key Features

Product Details

  • Check Mark
    With 48 wells, this gel is a great balance between high-throughput and high resolution.
  • Check Mark
    Loadable by single-channel and multi-channel pipettes.
  • Check Mark
    Tris-HCl gel chemistry: compatible with Tris-HCl running buffer and Tris-Glycine transfer buffer.
  • Check Mark
    Simply load samples into the wells and run electrophoresis.
  • Check Mark
    Wet transfer is recommended.

Specifications

  • Check mark
    128 mm * 82 mm length and width.
  • Check mark
    10% acrylamide gels: suitable for proteins between 25 and 100 kDa.
  • Check mark
    6% acrylamide gels: suitable for proteins between 50 and 250 kDa.
  • Check mark
    Number of wells: 48.
  • Check mark
    Well volume: 56 µL.
  • Check mark
    Recommended sample volume: 10-25 µL.
  • Check mark
    Shelf life when stored at 4 °C: 1 year from casting date.

Add-ons

Blotting Paper

Precut sheets ideal for conducting transfer with G96 and G48 Precast Gels

Order Now

Need answers?

Frequently Asked Questions

How long are the gels stable?
Our precast gels are stable for 1 year from the casting date, denoted on each gel as the expiration date.
Are custom gels available?
Yes, gels can be customized with different amounts of acrylamide depending on your protein separation needs.
What power supplies are compatible with the HT-1?
The HT-1 is compatible with standard lab power supplies using banana plugs. Recommended specifications include adjustable voltage and current up to 100 V and 400 mA, and at least 75 W of power.
What transfer methods are compatible with the G-Blot?

Wet transfer is recommended for use with the G-Blot system.

Should I use nitrocellulose or PVDF membranes for transfer?

Both membrane types are compatible with the G-Blot. The best membrane for your experiment will depend on your target proteins, detection methods, and antibodies.

Ready to accelerate your workflow?

Order Now